Gutter brackets should
be fixed to fascia board
at 900mm centres using
copper nails or other
appropriate fixings.
Gutter lengths should be
loosely laid in to bracket to
calculate correct length and
cut appropriately using a fine
tooth saw.
Outlets should be placed
in position and secured by
hooking under the front
scroll of the gutter and roll
in to place. The tabs on the
back of the outlet should
be folded down securely to
fix the outlet in place. The
outlet hole 75mm diameter
should be drilled using a
tank cutter. The hole should
be de-burred.
Gutters should be joined
using a joint strip. Hook
the joint strip under the
front scroll of the gutter
and roll to follow the gutter
profile. Keep the joint tight
to the gutter to compress
the rubber gaskets. Ensure
the joint is equally spaced
over the adjoining gutter/
component sections. The
tabs on the back of the
joint should be folded down
securely to fix the joint in
place. Gutter internal and
external angles should be
joined the same way.
Once gutter length is
complete, sit gutter firmly
in to gutter brackets. Fold
down tabs on front and rear
of fascia bracket to secure
gutter in place.
Stop ends are handed and
are fixed by silver soldering.
Each joining surface should
be cleaned with wire wool.
Flux should be applied to
joining surfaces. Heat using
a blow torch until flux begins
to bubble. Apply solder to
joint gap to seal. Please note
discolouration of the gutter
will occur due to the heat
applied. This will disappear in
time as the gutter weathers.